Abstract
This study investigates the effect of England's Warm Front energy efficient refurbishment scheme on winter thermal comfort in low-income dwellings. The analysis is based on an extensive survey of some 2500 dwellings selected from five major urban areas in England over the winters of 2001/02 and 2002/03. The surveys were carried out either before or after the introduction of retrofit insulation and energy efficient heating system. Self-reported thermal comfort (measured on a seven-point scale) and indoor temperature in the living room and in the main bedroom were recorded twice daily at 8 a.m. and 7 p.m. over 11 consecutive days. Results show that Warm Front was effective in increasing the mean indoor temperature from 17.1 °C to 19.0 °C leading to an increase in the proportion of households feeling thermally 'comfortable' or warmer from 36.4% to 78.7%. Warm Front also led to a slight increase in the whole house neutral temperature, i.e. the temperature at which most residents feel thermal neutrality, from 18.9 °C to 19.1 °C mainly from reduced clothing level associated with greater energy efficiency. Predicted Mean Vote, which is the standard thermal comfort model in ISO Standard 7730 predicted a higher neutral temperature of 20.4 °C compared to 18.9 °C found to be ideal among the average Warm Front households.
Original language | English |
---|---|
Pages (from-to) | 1228-1236 |
Number of pages | 9 |
Journal | Building and Environment |
Volume | 44 |
Issue number | 6 |
DOIs | |
Publication status | Published - Jun 2009 |
Externally published | Yes |
Keywords
- Energy efficiency
- Fuel poverty
- Indoor temperature
- PMV
- Take-back
- Thermal comfort
ASJC Scopus subject areas
- Environmental Engineering
- Civil and Structural Engineering
- Geography, Planning and Development
- Building and Construction