TY - GEN
T1 - A novel compensation strategy of actual commutations for ground leakage current reduction in PV transformerless converters
AU - Buticchi, G.
AU - Franceschini, G.
AU - Lorenzani, E.
AU - Barater, D.
AU - Fratta, A.
N1 - Copyright:
Copyright 2011 Elsevier B.V., All rights reserved.
PY - 2010
Y1 - 2010
N2 - The design of a PV grid-connected converter usually comprehends a galvanic isolation between the grid and the photovoltaic panels. Recently, for low power applications, the galvanic isolation has been removed with the aim to increase efficiency and reduce the cost of the converter. Due to the presence of a parasitic capacitance between the photovoltaic cells and the metal frame of the PV panel, usually connected to earth, a high value of common mode current (i.e. ground leakage current) can arise. In order to limit the ground leakage current (which deteriorates the power quality and generates EMI), new converter topologies have been proposed. This paper deals with a particular topology that, working in conjunction with a compensation strategy of power switches actual commutations, can guarantee low ground leakage current regardless the parameters tolerance of the power circuit. Simulation and experimental results confirm the effectiveness of the proposed solution.
AB - The design of a PV grid-connected converter usually comprehends a galvanic isolation between the grid and the photovoltaic panels. Recently, for low power applications, the galvanic isolation has been removed with the aim to increase efficiency and reduce the cost of the converter. Due to the presence of a parasitic capacitance between the photovoltaic cells and the metal frame of the PV panel, usually connected to earth, a high value of common mode current (i.e. ground leakage current) can arise. In order to limit the ground leakage current (which deteriorates the power quality and generates EMI), new converter topologies have been proposed. This paper deals with a particular topology that, working in conjunction with a compensation strategy of power switches actual commutations, can guarantee low ground leakage current regardless the parameters tolerance of the power circuit. Simulation and experimental results confirm the effectiveness of the proposed solution.
UR - http://www.scopus.com/inward/record.url?scp=78751503835&partnerID=8YFLogxK
U2 - 10.1109/IECON.2010.5675045
DO - 10.1109/IECON.2010.5675045
M3 - Conference contribution
AN - SCOPUS:78751503835
SN - 9781424452262
T3 - IECON Proceedings (Industrial Electronics Conference)
SP - 3179
EP - 3184
BT - Proceedings - IECON 2010, 36th Annual Conference of the IEEE Industrial Electronics Society
T2 - 36th Annual Conference of the IEEE Industrial Electronics Society, IECON 2010
Y2 - 7 November 2010 through 10 November 2010
ER -