TY - GEN
T1 - Automatic detection of the macula in retinal fundus images using seeded mode tracking approach
AU - Wong, Damon W.K.
AU - Liu, Jiang
AU - Tan, Ngan Meng
AU - Yin, Fengshou
AU - Cheng, Xiangang
AU - Cheng, Ching Yu
AU - Cheung, Gemmy C.M.
AU - Wong, Tien Yin
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2012
Y1 - 2012
N2 - The macula is the part of the eye responsible for central high acuity vision. Detection of the macula is an important task in retinal image processing as a landmark for subsequent disease assessment, such as for age-related macula degeneration. In this paper, we have presented an approach to automatically determine the macula centre in retinal fundus images. First contextual information on the image is combined with a statistical model to obtain an approximate macula region of interest localization. Subsequently, we propose the use of a seeded mode tracking technique to locate the macula centre. The proposed approach is tested on a large dataset composed of 482 normal images and 162 glaucoma images from the ORIGA database and an additional 96 AMD images. The results show a ROI detection of 97.5%, and 90.5% correct detection of the macula within 1/3DD from a manual reference, which outperforms other current methods. The results are promising for the use of the proposed approach to locate the macula for the detection of macula diseases from retinal images.
AB - The macula is the part of the eye responsible for central high acuity vision. Detection of the macula is an important task in retinal image processing as a landmark for subsequent disease assessment, such as for age-related macula degeneration. In this paper, we have presented an approach to automatically determine the macula centre in retinal fundus images. First contextual information on the image is combined with a statistical model to obtain an approximate macula region of interest localization. Subsequently, we propose the use of a seeded mode tracking technique to locate the macula centre. The proposed approach is tested on a large dataset composed of 482 normal images and 162 glaucoma images from the ORIGA database and an additional 96 AMD images. The results show a ROI detection of 97.5%, and 90.5% correct detection of the macula within 1/3DD from a manual reference, which outperforms other current methods. The results are promising for the use of the proposed approach to locate the macula for the detection of macula diseases from retinal images.
UR - http://www.scopus.com/inward/record.url?scp=84880934895&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2012.6347103
DO - 10.1109/EMBC.2012.6347103
M3 - Conference contribution
C2 - 23367038
AN - SCOPUS:84880934895
SN - 9781424441198
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 4950
EP - 4953
BT - 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012
T2 - 34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2012
Y2 - 28 August 2012 through 1 September 2012
ER -