Caractérisation du profil biométrique oculaire d'une population myope fort: la myopie forte correspond-elle un phénotype homogne ?

Translated title of the contribution: Characterization of the biometric eye profile of a high myopic population: Does high myopia correspond to a homogenous phenotype?

S. Auriol, J. Butterworth, M. MacÉ, W. Meng, F. Malecaze

Research output: Journal PublicationArticlepeer-review

1 Citation (Scopus)

Abstract

Purpose: High myopia is a public health problem because of its high prevalence and is a major cause of blindness. The physiopathology of myopia remains unknown and mechanisms causing the disease are most probably complex, combining acquired environmental and genetic factors. The most recent data suggest that genetic determinisms of high myopia could be highly dependent on subject phenotype. The aim of this study was to analyse the ocular components of a high myopic population to verify whether high myopia corresponds to a homogeneous phenotype. Patients and methods: We analysed the biometric characteristics of 718 myopic eyes with a spherical equivalent of less than -5 diopters. The biometric parameters (corneal radius, axial length, and intraocular pressure) were compared controlling for sex and the degree of myopia. Results: We found a difference between the phenotype of males and females. For men, axial length was the only determinant of the myopic phenotype, whereas for women, the myopic phenotype was determined by axial length and corneal radius. This difference between the phenotypes was more evident for myopia with a spherical equivalent greater than -10 diopters (moderate myopia). This difference between males and females disappeared in myopia less than -15 diopters. Conclusion: There are intersex differences considering the high myopia phenotype at a spherical equivalent less than -5 diopters. However, this difference disappears for extremely high myopia with a spherical equivalence of less than -15 diopters.

Translated title of the contributionCharacterization of the biometric eye profile of a high myopic population: Does high myopia correspond to a homogenous phenotype?
Original languageFrench
Pages (from-to)217-228
Number of pages12
JournalJournal Francais d'Ophtalmologie
Volume34
Issue number4
DOIs
Publication statusPublished - Apr 2011
Externally publishedYes

ASJC Scopus subject areas

  • Ophthalmology

Fingerprint

Dive into the research topics of 'Characterization of the biometric eye profile of a high myopic population: Does high myopia correspond to a homogenous phenotype?'. Together they form a unique fingerprint.

Cite this