TY - GEN
T1 - Diagnosis of incipient faults in PMSMs with coaxially insulated windings
AU - Barater, Davide
AU - Buticchi, Giampaolo
AU - Gerada, Chris
AU - Arellano-Padilla, Jesus
N1 - Copyright:
Copyright 2014 Elsevier B.V., All rights reserved.
PY - 2013
Y1 - 2013
N2 - Early detection of incipient faults in AC drives is one of the most difficult challenges for condition monitoring, especially for faults related to insulation degradation of the windings. This is because insulation degradation is very difficult to be detected on-line, so these faults may pass unnoticed before turning into a major faults. This paper looks at the feasibility of using coaxially insulated windings not only to increase reliability against winding insulation problems, but as an alternative to advance condition monitoring that may be suitable for the detection of insulation degradation, and other faults not easily detected by conventional schemes such as demagnetization issues, and the presence of inter-turn short circuits. The concept of insulation degradation for the case of coaxially insulated windings is analytically considered in this work and a novel condition monitoring alternative proposed. The proposed scheme and winding topology are extensively evaluated numerical to determine their feasibility to drive condition monitoring.
AB - Early detection of incipient faults in AC drives is one of the most difficult challenges for condition monitoring, especially for faults related to insulation degradation of the windings. This is because insulation degradation is very difficult to be detected on-line, so these faults may pass unnoticed before turning into a major faults. This paper looks at the feasibility of using coaxially insulated windings not only to increase reliability against winding insulation problems, but as an alternative to advance condition monitoring that may be suitable for the detection of insulation degradation, and other faults not easily detected by conventional schemes such as demagnetization issues, and the presence of inter-turn short circuits. The concept of insulation degradation for the case of coaxially insulated windings is analytically considered in this work and a novel condition monitoring alternative proposed. The proposed scheme and winding topology are extensively evaluated numerical to determine their feasibility to drive condition monitoring.
KW - Incipient Fault Detection
KW - Motor Control
KW - PMSM
KW - Winding Fault Diagnosis
UR - http://www.scopus.com/inward/record.url?scp=84893547878&partnerID=8YFLogxK
U2 - 10.1109/IECON.2013.6699567
DO - 10.1109/IECON.2013.6699567
M3 - Conference contribution
AN - SCOPUS:84893547878
SN - 9781479902248
T3 - IECON Proceedings (Industrial Electronics Conference)
SP - 2756
EP - 2761
BT - Proceedings, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society
T2 - 39th Annual Conference of the IEEE Industrial Electronics Society, IECON 2013
Y2 - 10 November 2013 through 14 November 2013
ER -