Abstract

While electrical machine designers typically go to great lengths to choose the optimal number of stator slots based on the electromagnetic performance, often the thermal aspects of this selection are overlooked. This article investigates the multi-domain impacts related to the slot number selection, combining both the electromagnetic and thermal aspects. Taking an existing 42-kW 4-pole, 12-slot electrical machine with Halbach-array surface-PM rotor, used within a more-electric marine engine as a case study, performance aspects of the machine with different slot numbers are investigated. The impact of slot number is compared considering the losses, output torque and its quality, as well as the peak temperature. Experimental tests are performed, verifying significant temperature reductions and performance entitlements when the optimal stator slot number from thermal point of view is selected. Finally general guidelines on slot number selection for temperature reduction are provided.

Original languageEnglish
Article number9137632
Pages (from-to)23-35
Number of pages13
JournalIEEE Transactions on Energy Conversion
Volume36
Issue number1
DOIs
Publication statusPublished - Mar 2021

Keywords

  • Thermal effects
  • multi-domain analysis
  • power density
  • slot number

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Slot Number Thermal Effects on Electrical Machines'. Together they form a unique fingerprint.

Cite this