Sparse dissimilarity-constrained coding for glaucoma screening

Jun Cheng, Fengshou Yin, Damon Wing Kee Wong, Dacheng Tao, Jiang Liu

Research output: Journal PublicationArticlepeer-review

89 Citations (Scopus)

Abstract

Objective: Glaucoma is an irreversible chronic eye disease that leads to vision loss. As it can be slowed down through treatment, detecting the disease in time is important. However, many patients are unaware of the disease because it progresses slowly without easily noticeable symptoms. Currently, there is no effective method for low-cost population-based glaucoma detection or screening. Recent studies have shown that automated optic nerve head assessment from 2-D retinal fundus images is promising for low-cost glaucoma screening. In this paper, we propose a method for cup to disc ratio (CDR) assessment using 2-D retinal fundus images. Methods: In the proposed method, the optic disc is first segmented and reconstructed using a novel sparse dissimilarity-constrained coding (SDC) approach which considers both the dissimilarity constraint and the sparsity constraint from a set of reference discs with known CDRs. Subsequently, the reconstruction coefficients from the SDC are used to compute the CDR for the testing disc. Results: The proposed method has been tested for CDR assessment in a database of 650 images with CDRs manually measured by trained professionals previously. Experimental results show an average CDR error of 0.064 and correlation coefficient of 0.67 compared with the manual CDRs, better than the state-of-the-art methods. Our proposed method has also been tested for glaucoma screening. The method achieves areas under curve of 0.83 and 0.88 on datasets of 650 and 1676 images, respectively, outperforming other methods. Conclusion: The proposed method achieves good accuracy for glaucoma detection. Significance: The method has a great potential to be used for large-scale population-based glaucoma screening.

Original languageEnglish
Article number7005484
Pages (from-to)1395-1403
Number of pages9
JournalIEEE Transactions on Biomedical Engineering
Volume62
Issue number5
DOIs
Publication statusPublished - 1 May 2015
Externally publishedYes

Keywords

  • cup to disc ratio
  • glaucoma screening
  • sparse dissimilarity-constrained coding

ASJC Scopus subject areas

  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Sparse dissimilarity-constrained coding for glaucoma screening'. Together they form a unique fingerprint.

Cite this