TY - JOUR
T1 - Time-to-Failure Analysis of Short-Duty Cycle, Inverter-Fed Electrical Machines Exposed to Prevailing Electrical Stress
AU - Ji, Yatai
AU - Giangrande, Paolo
AU - Wang, Huanran
AU - Zhao, Weiduo
AU - Madonna, Vincenzo
AU - Zhang, He
AU - Galea, Michael
N1 - Publisher Copyright:
© 1965-2011 IEEE.
PY - 2023/12/1
Y1 - 2023/12/1
N2 - Compact and efficient electric drives are desirable in transport applications and an increased dc-link voltage value combined with fast-switching devices represents a promising solution for achieving light and energy-efficient systems. Nonetheless, the higher dc bus voltage and wide-bandgap device greatly raise the electrical stress (i.e., maximum interturn voltage) of inverter-fed electrical machines (EMs) insulation jeopardizing the overall reliability. Thus, the lifetime prediction of EMs gained more attention recently. Short-duty cycle EMs are commonly employed in more electric aircraft (MEA) applications, and different from EMs for continuous operations, as they could operate under higher insulation stress due to their short duration of operation. In this article, the time-to-failure analysis on short-duty cycle, inverter-fed EMs is presented relying on the physics of failure approach. Electrical stress is assumed to be the dominant aging factor and the lifetime model based on the inverse power law is developed and tuned according to the collected experimental data. Two typical case study scenarios for MEA applications are discussed and the time-to-failure is calculated via the built lifetime model with a special focus on interturn insulation.
AB - Compact and efficient electric drives are desirable in transport applications and an increased dc-link voltage value combined with fast-switching devices represents a promising solution for achieving light and energy-efficient systems. Nonetheless, the higher dc bus voltage and wide-bandgap device greatly raise the electrical stress (i.e., maximum interturn voltage) of inverter-fed electrical machines (EMs) insulation jeopardizing the overall reliability. Thus, the lifetime prediction of EMs gained more attention recently. Short-duty cycle EMs are commonly employed in more electric aircraft (MEA) applications, and different from EMs for continuous operations, as they could operate under higher insulation stress due to their short duration of operation. In this article, the time-to-failure analysis on short-duty cycle, inverter-fed EMs is presented relying on the physics of failure approach. Electrical stress is assumed to be the dominant aging factor and the lifetime model based on the inverse power law is developed and tuned according to the collected experimental data. Two typical case study scenarios for MEA applications are discussed and the time-to-failure is calculated via the built lifetime model with a special focus on interturn insulation.
UR - http://www.scopus.com/inward/record.url?scp=85173006293&partnerID=8YFLogxK
U2 - 10.1109/TAES.2023.3317355
DO - 10.1109/TAES.2023.3317355
M3 - Article
AN - SCOPUS:85173006293
SN - 0018-9251
VL - 59
SP - 9368
EP - 9378
JO - IEEE Transactions on Aerospace and Electronic Systems
JF - IEEE Transactions on Aerospace and Electronic Systems
IS - 6
ER -